The Advantages of Row- and Rack-oriented Cooling Architectures for Data Centers
The traditional room-oriented approach to data center cooling has limitations in next-generation data centers. Next-generation data centers must adapt to

air conditioning unit  The purpose of the air conditioning system for the data center is to efficiently capture this complex flow of waste heat and eject it from the room. Room-based cooling is the historical method for accomplishing data center cooling. In this approach, one or more air conditioning systems, working in parallel, push cool air into the data center while drawing out warmer ambient air. The basic principle of this approach is that the air conditioners not only provide raw cooling capacity, but they also serve as Read More
Quote-to-Order (Q2O) Systems
Quote-to-order (Q2O) solutions (sometimes known as configure, price, and quote or CPQ) enable manufacturers to mobilize their mass customization initiatives. These systems can reduce time-consuming...
Start evaluating software now
Country:

 
   

 Security code
Already have a TEC account? Sign in here.
 
Don't have a TEC account? Register here.

Documents related to » air conditioning unit


PTC Live Global 2013: All About Design for “Servitization” —Part One
This was my third time attending the PTC Live Global (formerly PlanetPTC Live) conference, and by now I can say with some conviction that, compared to its large

air conditioning unit  the equipment. Given that air conditioning costs can sometimes amount to around 40 percent of a commercial customer’s total energy bill, this is not an inconsiderable value proposition. As another example, Emerson’s Climate Technologies recently made a strategic decision to focus on sensor-based diagnostics as a differentiator. The initial reason for equipping the compressors with sensors was to measure use and changes in electric amperage, which is often a key performance indicator (KPI) for a variet Read More
Vendors Jostle and Profess Economic Stimulus Readiness - Part III
Part I of this series analyzed the opportunity as well as the related attached strings stemming from the American Recovery and Reinvestment Act of 2009 (ARRA

air conditioning unit  engineer,  heating, ventilation, and air-conditioning [HVAC]  engineer, etc.) included a jumble of wasteful and unproductive point-to-point interactions. A much better way of late has been a hub-and-spoke interoperable information exchange (a repository) amongst these participants with a  Building Information Model (BIM)  at the information hub. A BIM repository enables efficient exchange and access for all relevant construction project information, such as the following: environmental data , design d Read More
Alice (or Allen) in MobileLand
Cell phones, smartphones, and similar mobile devices are beginning to play an active role in customer relationship management; many of these handheld devices

air conditioning unit  dollar heating, ventilating, and air conditioning (HVAC) manufacturer, found that prior to the use of such devices, it was having trouble with the amount of time it would take from when it first identified a need for parts for repair or replacement, to the actual installation of the parts because of the length of time it would take to get the parts to the customer. So, one of the company's key goals was to reduce this amount of time, which was around six weeks. By using handheld devices that facilitated o Read More
Management Strategy for Network Critical Physical Infrastructure
Network-critical physical infrastructure includes power, cooling, racks and physical structure, security and fire protection, cabling, management systems, and

air conditioning unit  buildings have a power, air conditioning, environmental monitoring, and security infrastructure in place. What distinguishes these systems from NCPI is the focus on availability of computing resources. The primary focus of building systems is the comfort of building inhabitants and traditional facilities functions such as building automation. The needs of these two entities differ widely. A standardized, adaptable, and integrated NCPI is essential to maintaining highly available and manageable networks. N Read More
Humidification Strategies for Data Centers and Network Rooms
In some circumstances, the air surrounding IT equipment can be harmful to internal electronic components and lead to failure and downtime. Reliance on precision

air conditioning unit  In some circumstances, the air surrounding IT equipment can be harmful to internal electronic components and lead to failure and downtime. Reliance on precision cooling solutions to maintain the proper humidity level in a computer room or data center doesn’t always assure proper humidity levels at the IT equipment air intake. Learn more about humidity, its effects, and its management in computer rooms and data centers. Read More
Strategies for Deploying Blade Servers in Existing Data Centers
Blade servers have a major advantage over traditional ones@improving processing ability while using less power per server. But, with their smaller footprint

air conditioning unit  120 cfm of cool air per kW of power rating. Most traditional data centers only provide 200-300 cfm of air per rack location, which is 10 times less air than fully populated rack of blade servers and limits the average rack power to below 2kW. A blade server which does not receive enough cool air will end up ingesting its own hot output air and overheat. This is by far the biggest challenge in blade deployments. Insufficient power distribution: Blade servers draw much more power than typical data center po Read More
One Vendor's Dedicated Governance, Risk Management, and Compliance Unit
SAP's governance, risk management, and compliance roadmap is still in its beginning stages. Only time will prove the vendor's delivery of true, tangible

air conditioning unit  GRC,governance,risk management,and compliance,Sarbanes-Oxley Act,SOX,regulatory compliance,enterprise resource planning,ERP,compliance management,information technology,IT,enterprise applications,service-oriented architecture,SOA Read More
Workpoint
Workpoint LLC , a business unit of Transaction Systems Architects, Inc. (NASDAQ: TSAI), provides business software and services that facilitate communication

air conditioning unit  digital workflow software,workflow automation software,workflows software,workpoint llc,workpoint software,workpoint workflow Read More
ICG Commerce
ICG Commerce provides a range of services for identifying, realizing, and improving procurement savings. The company's services go beyond finding unit cost

air conditioning unit   Read More
Case Study: Concert GmbH
Management at Concert GmbH, a company specializing in the production of non-woven air-laid fabrics, realized that the company had a lot of different custom

air conditioning unit  the production of non-woven air-laid fabrics, realized that the company had a lot of different custom applications running in its plants. Much of the production management was being handled manually—not in keeping with the nature of the company. After selecting a production management solution, Concert realized a return on investment in less than one year. Learn why. Read More
SouthWare Excellence Series: Making Excellence Easier Part Three: Application Analysis
The system supports a completely user-defined set of critical success factors for each business, business unit, or even individual employee.

air conditioning unit  great plains software,great plains training,hosted accounting software,hse software,infor erp,internet accounting software,inventory management system,manufacturing business software,manufacturing scheduling software,manufacturing software,mas software,mas200,mas90,mas90 accounting software,mas90 software Read More
Software Size Units
The conventional unit of measurement for software size is the point. Unfortunately, the point-based measurement system fails to account for many of the

air conditioning unit   Read More
Agresso + CODA, VITA + Link (+ CODA 2go): What's the Sum? - Part 2
Part 1 of this blog series described Unit 4 Agresso’s (or Agresso in further text) dual product strategy following its acquisition of CODA in 2008. The post

air conditioning unit  most SOA platforms are fairly evenly matched in that regard. If there is something that differentiates the Coda 2link's performance from, say, SAP NetWeaver , IBM WebSphere , or Oracle Fusion Middleware (OFM ) connection capabilities, then users need to know that, and why it is better. CODA believes that its unique selling proposition (USP ) with CODA Link is the extent of its coverage. Namely, all of the granular functions within CODA are available as Web Services, which means that anything that users Read More
The Benefits and Challenges of Globalization: An Economist Intelligence Unit Executive Summary
In a world with few constants, sustaining growth and outpacing competition are key concerns for just about every company, regardless of industry, geography, or

air conditioning unit   Read More

Recent Searches
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Others